RAD-XAI: Radiographic Deep Explainable-AI Framework

Explainable AI for Pneumonia Detection from Chest X-Rays

Python PyTorch License: MIT


Tab:explain prediction

What Is This Project?

Most AI research asks one question: "Is the model accurate?"

This project asks a harder, more important question: "Can we trust why the model made that decision?"

In medicine, this difference is everything. An AI model can be 99% accurate and still be making decisions for the wrong reasons, and when it fails, you have no way to understand why or catch it in time.

We trained three deep learning models to detect pneumonia from chest X-rays, then used XAI (Explainable AI) tools to evaluate not just what each model decided but how trustworthy its reasoning was. Every prediction is accompanied by a Grad-CAM heatmap showing exactly where in the X-ray the model was looking, and three quality metrics that verify whether that heatmap can actually be trusted.


What Problem Does It Solve?

Pneumonia is frequently missed in chest X-rays, especially in early stages and misdiagnosis can be life-threatening. AI can assist radiologists, but only if doctors can verify the AI's reasoning before acting on it. A black-box that says "Pneumonia: 98% confidence" is not clinically usable.

This project solves that by providing:

Tab:Patient browser

  • A pneumonia classifier achieving AUC above 0.98 across all three models
  • Grad-CAM heatmaps visual overlays showing where each model focused on the X-ray
  • Three XAI quality metrics verifying whether the heatmaps are genuine and consistent
  • Multi-model comparison: CNN baseline, medical CNN, and Vision Transformer
  • Threshold analysis across 99 operating points to find the safest clinical setting
  • Case study analysis across four clinical scenarios: correct catches, misses, and false alarms

Tab:threshold analysis

---

Models

Model Architecture Role
ResNet-18 Standard CNN Baseline, widely used, well understood
DenseNet-121 Dense CNN Validated in medical imaging (CheXNet architecture)
ViT-Tiny Vision Transformer Modern lightweight architecture tests XAI compatibility

XAI Metrics Explained

Three metrics judge whether a heatmap is trustworthy:

Concentration ↑ (Higher = Better)

Is the model looking at one specific spot, or staring at everything at once? Think of it as a spotlight, a focused spotlight on one actor is useful; a spotlight covering the whole stage tells you nothing.

  • 1.0 = tight, precise spotlight
  • 0.5 = attention spread broadly
  • 0.0 = looking everywhere equally, useless heatmap

Faithfulness Drop ↑ (Higher = Better)

If you cover the highlighted region, does the model's confidence drop significantly?

  • 1.0 = covering that region destroys model confidence - the heatmap is genuine
  • 0.0 = covering it changes nothing - the heatmap is misleading
  • Negative = covering it actually increases confidence - the model was being misled by that region

GC/GC++ Agreement ↑ (Higher = Better)

Do Grad-CAM and Grad-CAM++ point at the same region when asked independently?

  • 1.0 = both methods agree completely, stable, verifiable explanation
  • 0.0 = they point at completely different regions, explanation cannot be trusted

Key Findings

Finding 1 - ResNet-18 is the most trustworthy model

Faithfulness 0.715 and Agreement 0.831. When correct, faithfulness = 0.763. When wrong, faithfulness = 0.533 (+23% gap). Explanation quality tracks prediction quality - the most honest model for clinical audit.

Finding 2 - DenseNet-121 is the most consistent explainer

Highest Agreement of all three: 0.885. Faithfulness gap of +0.439 between correct (0.701) and wrong (0.263) predictions. A faithfulness score below 0.30 reliably identifies wrong predictions - making it usable as a live clinical safety flag.

Finding 3 - ViT-Tiny is accurate but unauditable

Concentration 0.900 (best of all models). But Agreement is 0.085 - near zero across the entire 624-image test set, in every scenario, whether the prediction was right or wrong. Gradient-based XAI methods (Grad-CAM, Grad-CAM++) are structurally incompatible with transformer architectures.

Finding 4 - The FN Perception Failure (most important finding)

In the False Negative case (real pneumonia, all 3 models predicted NORMAL):

  • All 3 models had faithfulness scores above 0.92 - the highest in the entire dataset
  • All 3 independently focused on the same lung region
  • All 3 were under 1% pneumonia confidence - completely, confidently wrong

A model can look at exactly the right place, faithfully use that region for its decision, and still fail to detect disease. This is a perception failure, not an attention failure. It is only detectable through XAI - accuracy metrics alone would never reveal it.

Finding 5 - Default threshold (0.50) is unsafe for clinical use

Threshold Missed Pneumonia Cases Recommendation
0.10 1–2 out of 390 Recommended for clinical use
0.50 (default) 4–9 out of 390 Not appropriate for medicine
0.90 14–18 out of 390 Misses too many cases

Dataset

Kaggle Chest X-Ray Images (Pneumonia)

https://www.kaggle.com/datasets/paultimothymooney/chest-xray-pneumonia

Split Normal Pneumonia Total
Train 1,341 3,875 5,216
Test 234 390 624

Project Structure

XAI_xray_analysis/
│
├── data/                          # Dataset
│   ├── train/
│   │   ├── NORMAL/
│   │   └── PNEUMONIA/
│   └── test/
│       ├── NORMAL/
│       └── PNEUMONIA/
│
├── model/                         # Saved trained model weights
│   ├── resnet18_pneumonia.pth
│   ├── densenet121_pneumonia.pth
│   └── vit_tiny_pneumonia.pth
│   ├── xai_case_analysis.py           # Generates the 4 clinical case studies (TP/TN/FN/FP)
│   ├── xai_quality_analysis.py        # Computes XAI metrics for all 624 test images
│   ├── xai_quality_full.csv           # Output: XAI metrics - 1,872 rows (624 × 3 models)
│   ├── xai_case_study.csv             # Output: 4 case study images × 3 models
│ 
│ 
├── pages/                         # Multi-page Streamlit app pages
│   ├── 1_Model_Performance.py
│   ├── 2_XAI_Quality_Study.py
│   └── 3_Case_Studies.py
│
├── src/                           # Core source modules
│   ├── gradcam.py                 # Grad-CAM heatmap generation
│   ├── models.py                  # Model definitions and loaders
│   ├── utils.py                   # Shared utilities (image loading, preprocessing)
│   └── xai_metrics.py             # Concentration, Faithfulness, Agreement
│
├── app.py                         # Main Streamlit app entry point
├── evaluate_all.py                # Runs full evaluation across all models and images
├── train.py                       # Model training script
├── xai_case_analysis.py           # Generates the 4 clinical case studies (TP/TN/FN/FP)
├── xai_quality_analysis.py        # Computes XAI metrics for all 624 test images
│
├── requirements.txt
└── README.md

Installation

Step 1 - Clone the repository

git clone https://github.com/yourusername/XAI_xray_analysis.git
cd XAI_xray_analysis

Step 2 - Create a virtual environment

# Create virtual environment
python -m venv venv

# Activate on Mac / Linux
source venv/bin/activate

# Activate on Windows
venv\Scripts\activate

Step 3 - Install dependencies

pip install -r requirements.txt

Key dependencies:

torch>=2.0.0
torchvision>=0.15.0
timm>=0.9.0
numpy>=1.24.0
pandas>=2.0.0
matplotlib>=3.7.0
opencv-python>=4.8.0
scikit-learn>=1.3.0
Pillow>=10.0.0
streamlit>=1.28.0
tqdm>=4.65.0

Step 4 - Download the dataset

  1. Go to https://www.kaggle.com/datasets/paultimothymooney/chest-xray-pneumonia
  2. Download and unzip the dataset
  3. Place the folders inside data/ so the structure matches above:
data/
├── train/
│   ├── NORMAL/
│   └── PNEUMONIA/
└── test/
    ├── NORMAL/
    └── PNEUMONIA/

Usage

1. Train the models

python train.py

Trains ResNet-18, DenseNet-121, and ViT-Tiny on the training set. Saved weights go into the model/ folder.

2. Evaluate model performance

python evaluate_all.py

Runs AUC, accuracy, sensitivity, and specificity across all 99 decision thresholds (0.01 to 0.99) for all three models.

3. Run XAI quality analysis

python xai_quality_analysis.py

Computes Concentration, Faithfulness Drop, and GC/GC++ Agreement for all 624 test images across all 3 models. Outputs xai_quality_full.csv (1,872 rows).

4. Run case study analysis

python xai_case_analysis.py

Selects representative images for all 4 clinical scenarios (TP, TN, FN, FP) and computes full XAI metrics. Outputs xai_case_study.csv.

5. Launch the interactive app

streamlit run app.py

Opens the multi-page Streamlit dashboard in your browser:

Page What it shows
Model Performance AUC curves, accuracy, threshold analysis across all 3 models
XAI Quality Study Concentration, Faithfulness, Agreement per model - correct vs wrong breakdown
Case Studies Side-by-side heatmap comparison for TP, TN, FN, FP cases

Results Summary

Model AUC Faithfulness Agreement Clinical Trust
ResNet-18 0.9851 0.715 0.831 Trustworthy
DenseNet-121 0.9850 0.587 0.885 Reliable
ViT-Tiny 0.9823 0.737 0.085 Unverifiable

What This Project Contributes

  • Multi-architecture XAI comparison across 1,872 datapoints - not just selected examples
  • Identification that ViT-Tiny is accurate but structurally unauditable with gradient-based XAI
  • Discovery of the FN perception failure - high faithfulness heatmaps do not prevent missed diagnosis
  • DenseNet-121 faithfulness as a clinical safety flag (threshold: 0.30)
  • Clinically appropriate decision threshold recommendation (0.10) over the naive default (0.50)

License

MIT License - free to use, modify, and distribute with attribution.


Acknowledgements

  • Dataset: Paul Mooney via Kaggle Chest X-Ray Images (Pneumonia)
  • DenseNet-121 architecture inspired by CheXNet - Rajpurkar et al. (2017)
  • Grad-CAM - Selvaraju et al., ICCV (2017)
  • Grad-CAM++ - Chattopadhyay et al. (2018)
  • Vision Transformer (ViT) - Dosovitskiy et al. (2020)

About

RAD-XAI is an explainable-AI framework for chest X‑ray pneumonia detection that benchmarks CNNs and ViTs using Grad‑CAM-based saliency maps and quantitative XAI metrics (concentration, faithfulness, agreement) to audit model reasoning and surface clinically unsafe failure modes beyond standard AUC/accuracy.

Topics

Resources

Stars

Watchers

Forks

Releases

No releases published

Packages

 
 
 

Contributors

Languages